-25℃ FREEZER MDF-C15

25℃ Freezer MDF-C15

Technical Parameters:

Model no MDF-C15
External Size(W*D*H) mm 690*744*1885
Internal Size(W*D*H) mm 410*410*670
Capacity 100L
Type Vertical
Temp. Range Temp. Range
Temp. Accuracy 0.1℃
Control System Microprocessor control, LED Digital Display
Alarm Method Sound beeps and lights flash
Refrigerator Direct refrigeration
Refrigerant R600a
Consumption 150w
Power Supply AC220V+10%,50/60Hz
Package Size(W*D*H) mm 610*625*950
Gross Weight 43kg
Read more

-25℃ FREEZER MDF-C15

25℃ Freezer MDF-C15

Technical Parameters:

Model no MDF-C15
External Size(W*D*H) mm 690*744*1885
Internal Size(W*D*H) mm 410*410*670
Capacity 100L
Type Vertical
Temp. Range Temp. Range
Temp. Accuracy 0.1℃
Control System Microprocessor control, LED Digital Display
Alarm Method Sound beeps and lights flash
Refrigerator Direct refrigeration
Refrigerant R600a
Consumption 150w
Power Supply AC220V+10%,50/60Hz
Package Size(W*D*H) mm 610*625*950
Gross Weight 43kg
Read more

MK-M96

96 Well Microplate Washer

MK-M96

Medallion Equipments

Technical Specifications:

Features:

  1. Microcomputer control, automatically complete the plate washing operation.
  2. The liquid level sensing function automatically detects the liquid level, and automatically alarms when the cleaning liquid is insufficient and the waste liquid is overflowing.
  3. The user-friendly operating system allows users to customize the plate type, set the number of washes, the amount of wash solution, the way to wash the plate, the suction point, the soaking and shaking time and other parameters.
  4. The wash head is self-balancing, has two-point aspiration, and performs bottom flushing.
  5. 2 kinds of Automatic washing, Soaking and Shaking, to reduce the interference adsorption during the reaction; time adjustable.

Technical Parameters:

Model MK-M96
Cleaning Head 8 channels and 12 channels
Microplate Types Four kinds, flat bottom, U bottom, V bottom, round bottom
Average Residue <1μl(per hole)
Liquid Suction Time 0.1~999.9 seconds adjustable, with an interval of 0.1 seconds
Line Flush Time 1~999 seconds, adjustable
Washing Programs Up to 200 programs
Display 7-inch touch display
Liquid Injection Channels 3(2 types of lotion and 1 type of distilled water)
Cleaning Needle Position 6 types(horizontal, left, middle, right, bottom, hole spacing)
Consumption 80W
Power Supply AC220V±10%, 50/60Hz; 110±10%, 60Hz
Packing Size(W*D*H) 720*480*400mm
Gross Weight 20kg
Read more

MCM-M180

Automatic Immune Analyzer

MCM-M180

ACCURATE TEST RESULT

  • Sample probe with function of clot detection
  • Reagent disk refrigerated at 2−8 °C
  • Unique design of reagent kits, non-contact mixing method
  • Non-contact multi-position mixing method of reaction disk
  • Precise magnetic particles separation technology
  • Quality control and calibrators need no pre-treatment
  • Query successful
  • Automatic Sample Clot Detection and Rejection
  • Fully Automated Operation
  • RS-232 or USB interface
  • LIMS compatible for seamless integration
  • Operates on 220V, 50 Hz AC
  • Touchscreen Interface

 

EFFICIENT WORKING MODE

  • Time to first result: 11 minutes
  • Batch test throughput up to 180 T/H
  • 90 sample positions
  • Flexible STAT priority function
  • 25 reagent positions
  • Reagents auto registered
  • Samples and consumables on-board loading

 

HUMANIZED FUNCTIONAL DESIGN

  • Unique sample rack design
  • Integrate reagent kits design, flexible test package setting
  • Intelligent & personalized software design
    • Test countdown
    • Standby countdown
    • Maintenance countdown

 

Reagent Panel

  • Thyroid
  • Fertility
  • Cardiac Marker
  • Liver Fibrosis
  • Bone metabolism
  • Anemia
  • Metabolism
  • Inflammation
  • Hypertension & Renal function
  • Infectious
  • Tumor Marker
  • Drug Monitoring

 

 

User Adjustable Settings:

  • Sample Types Supported:
    • Serum
    • Plasma
    • Urine
  • Sample Volume:
    • 50–250 µL (test dependent)
  • Sample Capacity:
    • Minimum 50 samples
    • Continuous loading platform for uninterrupted workflow
  • Onboard Reagent Capacity:
    • 24 or more reagents simultaneously
  • Test Parameters:
    • As per user/end-user requirements (to be defined by the procuring agency)

 

Displayed Parameters / Assay Capabilities:

  • Automatic testing for analytes related to:
    • Cancer
    • Infectious Diseases
    • Cardiovascular Disease
    • Thyroid Disease
    • Fertility/Hormones
    • Polio
    • Vitamins
    • Hepatitis Markers
Read more

AUTO ELISA PROCESSOR MES-1000

 

Auto ELISA Processor MES-1000:

Features:

1. 1 robotic arm, 1 pipetting probe(10~1000μl).
2. 2 unit 96 well microplates(independent incubating).
3. 1 unit reader& washer (auto reading and washing)

Technical Parameters:

Model No. MES-1000
Sample Unit Sample Racks Standard 192 sample posion (expandable,
up to 384)
Pipetting 10~1000μl
Dispensing System 1 aspiring-dispensing probe with X-Y-Z
movement;
Reagent Unit Reagent Racks Universal reagent position: standard 6

universal reagent positions (expandable,
up to 32);

Pipetting Range 10~1000μl,1ul stepping
Pipetting precision (100μl) CV≤0.5%
Dispensing Time 5 minutes to whole96well microplates
Incubation Unit Incubation 2 independent incubators
Temperature Range RT to 45 °C
Temperature Accuracy ±0.5°C
Washing Unit Washing Probes Two line 8-nozzle manifolds
Wash Containers 2 wash buffers 2L, 1 distilled water, 1 waste
water
Washing Residual <2μ
Reading Unit Reading Channels 8 independent photometric channels, mono
and dichromic reading
Absorbance 0.0 ~3.0 OD
Spectral Range 400-700nm
Optical Filters 2standardfilters (450,630nm); 2 more on
request (405nm/450nm/492nm/630nm)
Working
Conditions
Power Supply AC220V±10%,50/60Hz, 110V±10%,
60Hz, 400W
Temperature 10〜30℃
Size & Weight External Size (W*D*H) 933*685*860mm
Net Weight 130kg
Package Size (W*D*H) 1085*840*1318mm
Gross Weight 180kg
Read more

Optical Coagulation Analyzer

Optical Coagulation Analyzer:
OCG-102:
Optical Coagulation Analyzer, used together with the test reagents, delivers quick lab-quality results that support clinical decisions in cardiology, surgery and intensive care. The first POCT coagulation analyzer that can test PT/INR, APTT, TT, FIB and ACT.
The first POCT coagulation analyzer that can test PT/INR, APTT, TT, FIB and ACT.
APPLICATIONS:
Screening test to assess the exogenous and endogenous coagulation system function
Monitoring anticoagulant treatment
Monitoring thrombolytic therapy
Monitoring the patient with certain disease, such as hepatopathy, infection, burn injury
Specification

Read more

Blood hematology analyzers DF50 CRP

Blood hematology analyzers DF50 CRP

Principles:

Flow cytometry (FCM) + Tri-angle laser scatter for WBC dierentiation
Impedance method for WBC, RBC and PLT test
Cyanide free colorimetry for HGB test
Latex-enhanced scattering immunoturbidimetry for CRP test

Parameters:

27 reportable parameters:
CRP, Hs-CRP, WBC, Neu#, Lym#=, Mon#, Eos#, Bas#, Neu%,
Lym%, Mon%, Eos%, Bas%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT,
MPV, PDW, PCT, P-LCR, P-LCC

6 research parameters:

ALY#, ALY%, LIC#, LIC%, NRBC#, NRBC%

3 histograms for WBC, RBC and PLT

Three DIFF scattergrams and one BASO scattergram for WBC differential.

Sample mode:

Whole blood, capillary whole blood and pre-diluted modes

Sample volume:

20μL

Linearity range:

WBC: 0.00-500.00×109/L
RBC: 0.00-8.50×1012/L
HGB: 0-250g/L
PLT: 0-5000×109/L
HCT: 0.0-67.0%
CRP: 0.2-320 mg/L

Repeatability:

WBC≤2.5%(4.0-15.0×109/L)
RBC≤1.5%(3.5-6.0×1012/L)
HGB≤1%(110-180g/L)
MCV≤1%(70-120fL)
PLT≤6.0%(100-149×109/L)
≤4.0%(150-500×109/L)

Test mode:

CBC, CBC+DIFF, CRP, CBC+CRP, CBC+DIFF+CRP

Read more

Blood Gas Analyzer

CALCULATION PARAMETERS:

Total 23 Parameters:

cH+, cH+(T), pH(T), pCO2(T), pO2(T), HCO3 std, HCO3 std, BB(B), BE(B),BE(ecf), ct CO2,
Ca++(7.4), AnGap, tHb(est), sO2(est), pO2(A-a), pO2(A-a)(T), pO2(a/A), pO2(a/A)(T), RI,
RI(T), pO2/FI O2, pO2(T)/FI O2

COMPONENTS:

Test Card:

Sample Type: Whole Blood
Sample Volume: 80ul
Reading Time: 30s
Suitable for Syringe and Capillary
Good correlation to reference method

Reagent Pack:

Stability and effectivity for 12 months
Shelf life: Up to 60 days after
installation

Quality control:

Internal electronic QC
External electronic simulated QC card
Three levels liquid quality control

Basic blood-gas Haematology Electrolyte Biochemistry
pH, pCO2, pO2 Hct K+, Na+, Ca++, Cl Glu, Lac
Read more

ELECTRIC BLOOD COLLECTION CHAIR MBD-A100

MBD-A100

Product Description:

  • Manual or electric control type for your choice.
  • Made of high-strength fiber material and poly-layer paint, more durable, easy to clean;
  • Designed with people-oriented idea, to meet the donor’s sense of security and comfort, to alleviate the psychological
    pressure, to ensure an easier and enjoyable process.
  • Mattress using a high-quality medical polyurethane foam molding leather, easy for clean and maintenance,
    anti-static and anti-fouling properties superior to other similar products.

Technical Parameters:

Model No MBD-A100
Seat section size(mm) 1800× 580
Seat secon height(mm) 500
Backing board turning angle 20 ° -70 °
Chair backward and forward lt angle 8° -15 °
Leg plate turning angle 20 ° -75 °
Handrail swing out angle 0 ° -30 °
Handrail’s moving distance 100mm
Handrail board size 450x160mm
Standard stroke 150mm
Lifting speed 3-25mm/s
Power supply AC220V/110V ±10%, 50/60Hz
Reading lamp power 60 W
Standard accessories Hand operation, handrail rack, multi media support, small table
Optional accessories LED hose-type reading lamp; movable assistant
desk; so velvet cover
Load capacity(kg) 160
Packing size(W*D*H)mm 1300×780×1250
Gross Weight (kg) 127
Read more

M-100

Inverted Microscope

M-100

Medallion Equipments

Technical Specifications:

Model M-100
Optical System Infinite Optical System
Viewing Head Trinocular Head Inclined at 30°, Interpupillary Distance 48~75mm
Eyepiece High-point, Extra Wide Field Eyepiece EW10X/22
Objective LWD Infinite Plan Objective 4X/0.1, WD 17.3mm
10X/0.25, WD 10mm
20X/0.4, WD 5.1mm
40X/0.6, WD 2.1mm
Infinite Plan Phase Objective PH10X/0.25, WD 10 mm
PH20X/0.4, WD 5.1mm
PH40X/0.65, WD 2.1mm
Nosepiece Quintuple Nosepiece
Condenser ELWD Condenser NA 0.3, LWD 72mm (Without Condenser 150mm)
Centering Centering Telescope(Φ30MM)
Phase Annulus 10X~20X, Phase Annulus Plate(Fixed)
10X~20X、40X Phase Annulus Plate(Adjustable)
Stage Plain Stage 160X250mm
Glass Insert
Attachable Mechanical Stage, X-Y Coaxial Control,Moving Rang120X78mm
Auxiliary Stages70X180mm
Terasaki Holder
Φ35mm Petri Dish Holder
Φ54mm Slide Glass Holder
Φ90mm Petri Dish Holder
Focusing Coaxial Coarse and Fine Adjustment, Fine Division 0.002mm, Coarse Stroke 37.7mm per Rotation, Fine Stroke 0.2mm per Rotation, Moving Range up 8mm, down 3mm
Illumination Halogen Lamp 6V/30W
LED
Filter Blue, Green and Ground Glass, Diameter 45mm
Power Supply AC110~220V, 50/60Hz
Accessories Inverted fluorescent attachment FL-100, Photo Attachment, Video Adapter with C Mount
Package Size 468*397*665mm
Gross Weight 15.5kg

Note: √ Standard Outfit, ●Optional

Read more