Automatic Hematology Analyzer MHA-40

Features
> WBC 3-part differential, 21 report parameters and 3 histograms
> 70 samples/hour
> Whole blood, micro-whole blood,pre-diluted blood
> 10.4 inch touch screen
> Storage capacity up to 500,000 samples, easy for users to manage and statistical analysis
> Optimize the liquid circuit reduce reagent consumption
> Build-in lyse position saving more space
> Multi-function USB extension to connect printer, scanner, mouse, data export, etc
> Bi-directional LIS, improve work efficiency and convenient data transfer

 

Feature Benefit
Accurate &

Reliable Result

– 21 parameters and WBC, RBC, PLT histograms <br> –

Showing pathological and morphological abnormalities flags

Easy Operation – Easy to operate – Throughput of 70 samples per hour <br> – Utilize 10.4 inch TFT Touch Screen to display all parameters and histograms <br> – Equipped with barcode reader <br> – Automatic sleep function
Full Traceability

System

– Original instrument, reagent, QC&Cali to present the quality

<br> – Tracing and traceability system

Affordable for Your Choice – Low cost for real benefits <br> – Little reagent consumption
Perfect QC Function – L-J,,X-B,X-R <br> – 3 levels of controls for daily QC with LevyJennings charts
Large Storage & Rich Interface – 500,000 results storage capacity <br> – 4 USB interface <br> – LAN port RJ45
User Friendly Design – 6ul for Microscale-whole blood testing <br> – Cyanide-free hemolytic reagent for HGB measurement. <br> – Automatic reagents remaining detection <br> – Bi-directional LIS/HIS
Parameters 21 parameters: WBC, NEU#, LYM#, MXD#, NEU%, LYM%, MXD%,

RBC, HGB, MCV, MCH, MCHC, RDW-CV, RDW-SD, HCT, PLT, MPV, PDW, PCT, P-LCR, P-LCC

3 Histograms WBC, RBC, PLT
Pathological and morphological abnormalities alarm Yes
Principles Impedance method for WBC, RBC and PLT counting
Throughput 70 test/hour
Display 10.4 inch TFT Touch Screen
Sampling Mode Manual Mode
Storage Capacity More than 500,000 results
Sample

Volume

Whole blood mode 6uL, Prediluted mode 20uL
Reagent Type One diluent and one lyse
Interface LAN port RJ45, 4 USB port
LIS/HIS Bi-directional
Read more

Digital Viscometer MBV-B2

Features:
*Central control circuit: 16-bit MCU.
*RTD temperature probe can monitor the temperature of the sample.
*LCD can display all information.
*Optional software: DV Program Control Download Software
& Data Collecting, Analysis, and Plot Software.

Technical Parameters:

Series BDV-2
Model MBV-B2
Measured Range

(mPas)

40-40M
Rotation Speed(rpm) 0.1-200 non-polar shift
Number of Spindle 6 (R2〜R7)
Measurement Accuracy ±1%(FS) (Newtonian Fluid)
Repeatability ±0.5%(FS) (Newtonian Fluid)
Power Supply AC 100-240V, 50/60HZ
Standard accessory RS232 standard output interface, RTD temperature probe
Optional accessory Specially used printer
L0 Spindle is for Option

Measured Range

(mPas)

3-60000
R1 Spindle is for Option

Measured Range

(mPas)

10-100000
Package Size(mm) 400*350*550
Gross Weight(kg) 10.5
Read more

Digital Viscometer MBV-B1

Features:
*Central control circuit: 16-bit MCU.
*RTD temperature probe can monitor the temperature of the sample.
*LCD can display all information.
*Optional software: DV Program Control Download Software
& Data Collecting, Analysis, and Plot Software.

Technical Parameters:

Series BDV-1
Model MBV-B1
Measured Range

(mPas)

80〜40M
Rotation Speed(rpm) 0.1*99.9 non-polar shift
Number of Spindle 6 (R2〜R7)
Measurement Accuracy ±1%(FS) (Newtonian Fluid)
Repeatability ±0.5%(FS) (Newtonian Fluid)
Power Supply AC 100-240V, 50/60HZ
Standard accessory RS232 standard output interface, RTD temperature probe
Optional accessory Specially used printer
L0 Spindle is for Option

Measured Range

(mPas)

6〜6000
R1 Spindle is for Option

Measured Range

(mPas)

20〜100000
Package Size(mm) 400*350*550
Gross Weight(kg) 10.5
Read more

Digital Viscometer MBV-A1

Features:
*Central control circuit: 16-bit MCU.
*RTD temperature probe can monitor the temperature of the sample.
*LCD can display all information.
*Optional software: DV Program Control Download Software
& Data Collecting, Analysis, and Plot Software.

Technical Parameters:

Series BDV-1
Model MBV-A1
Measured Range

(mPas)

12〜6M
Rotation Speed(rpm) 0.1*99.9 non-polar shift
Number of Spindle 4 (L1〜L4)
Measurement Accuracy ±1%(FS) (Newtonian Fluid)
Repeatability ±0.5%(FS) (Newtonian Fluid)
Power Supply AC 100-240V, 50/60HZ
Standard accessory RS232 standard output interface, RTD temperature probe
Optional accessory Specially used printer
L0 Spindle is for Option

Measured Range

(mPas)

0.6〜6000
R1 Spindle is for Option

Measured Range

(mPas)

/
Package Size(mm) 400*350*360
Gross Weight(kg) 9
Read more

Portable Multi parameter Water Quality Meter MPH-900

Features:
PH:
*Multiparameter water quality meter is equipped with a 3.5 inches backlit LCD display.
*1 to 5 points calibration with automatic recognition for USA, NIST, and DIN buffers.
*Automatic electrode diagnosis shows the pH slope and offset.
ORP:
*1-point offset calibration allows adjusting the displayed value to a known standard.
*Relative and absolute millivolt modes ensure reliable ORP measurements.
Ion Concentration:
*2 to 5 points calibration, including the 8 concentration points can be selected.
*Direct ion concentration readout simplifies the measurement process.
*Automatic electrode diagnosis shows the calibration points and slopes.
*Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency. Conductivity/TDS/Salinity/Resistivity:
*1 to 5 points calibration with automatic recognition for conductivity standards.
*Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.
*Automatic electrode diagnosis shows the calibration points and factors.
Dissolved Oxygen:
*1 or 2 points calibration using the air-saturated water or zero oxygen solution.
*Salinity and barometric pressure compensations eliminate the measurement error. Other Features:
*Automatic temperature compensation ensures accurate readings over the entire range.
*Auto-Read function senses and locks the measurement endpoint.
*Calibration due alarm prompts user to calibrate the meter regularly.
*Auto-Power Off effectively conserves battery life.
*Setup menu allows setting the number of calibration points, resolution, stability criteria, temperature unit, date and time, etc..
*Reset function automatically resumes all settings back to the factory defaults.
*Expanded memory stores or recalls up to 500 data sets.
*USB communication interface is easy to transfer data to PC.
Multi-mode power scheme (batteries, power adapter and USB port) ensures that using the meter smoothly.

Accessories:

pH/conductivity/dissolved oxygen electrode, temperature probe, pH standard buffer, conductivity standard solutions, dissolved oxygen electrolyte, membrane cap, carrying case.

Technical Parameters:

Model PH-900P
pH Range -2.000~20.000pH
Resolution 0.001,0.01, 0.1pH, selectable
Accuracy ±0.002pH
Calibration Points 1 to 5 points
pH Buffer Options USA, NIST, DIN, 2 custom buffers
ORP(optional) Range ±1999.9mV
Resolution 0.1, 1mV, selectable
Accuracy ±0.2mV
Calibration Points 1 point
lon(optional) Range 0.001 ~19999 (depending on the range of ISE)
Resolution 0.001,0.01,0.1,1
Accuracy ±0.5% F.S. (monovalent),±1%F.S. (divalent)
Measurement Units ppm, mg/L, mol/L, mmol/L
Calibration Points 2 to 5 points (0.001,0.01, 0.1,1,10, 100,1000, 10000)
Conductivity Range 0.1 ~2卩S/cm(CON-0.1,optional); 2*-20mS/cm(CON-1 .standard); 20~200mS/cm(CON・10,optional)
Resolution 0.001,0.01,0.1,1
Accuracy ±0.5% F.S.
Calibration Points 1 to 5 points
Calibration Solutions 10pS/cm, 84pS/cm, 1413pS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear (0.0~10.0%/°C), pure water
Reference Temperature 20/25°C
Cell Constant K=0.1,1, 10 or custom
TDS Range 0-10.00,100.0,1000ppm, 10.00, 200.0ppt
Resolution 0.01,0.1,1
Accuracy ±1%F.S.
TDS Factor 0.1-1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01
Accuracy ±1%F.S.
Resistivity Range 0.00~20.00MQ
Resolution 0.01
Accuracy ±1%F.S.
DO Range 0.00~20.00mg/L, 0.0-200.0% saturation
Resolution 0.01 mg/L, 0.1%
Accuracy ±0.2mg/L, ±2.0%
Calibration Points 1 or 2 points
Barometric Pressure Correction 60.0~112.5kPa/450~850mmHg, manual
Salinity Correction 0.0~50.0g/L, manual
Other

Specifications

Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets. USB communication interface
Power Requirements 3*1.5V AA batteries or DC5V power adapter
Dimension 170*85*30mm
Net Weight 300g
Packing Size 450*320*100mm
Gross Weight 2kg
Read more

Dental Chair MEDALLION-2301

Application:

Dental chairs are used in stomatology, medical institutions, or dental clinics. The dental chair is used by trained dentists or dental technicians for oral diagnosis, treatment, and surgery.

Technical Parameters:

Model MEDALLION-2301
High-speed handheld machinery tube 2 sets
Low-speed handheld machinery tube 1 sets
Ceramic spittoon 1 sets
Motor-driven dental chair control system 1 sets
24V DC mute motor 1 sets
Dimmable induction LED oral cavity light 1 sets
Low-pressure film viewer 1 sets
Independent saliva ejector with high &low suction 1 sets
Handpiece purified water switch system 1 sets
Tap-mountad instrumant fray with air brake 1 sets
3-way syring (cold/hot water) 1 sets
Multifunctional foot switch 1 sets
Operating stool 1 sets
Power Supply 220V±10%, 50/60Hz;110±10%, 60Hz
Package Size(L*W*H) 1400*1000*1000 mm
Net/Gross Weight 135kg/180kg

Optional Accessories:

High speed handheld machinery 2 sets
Low speed handheld machinery 1 sets
Fiber high speed handheld machinery 1 sets
Fiber low speed handheld machinery 1 sets
Built-in dental cleaning machine 1 sets
Optical fiber circuit board + optical fiber
hand-held mechanical tube
1 sets
Dental endoscope 1 sets
Dental built-in light curing 1 sets
Built-in electric motor kit 1 sets
Operating stool 1 sets
Oilless Air Compressor(BKHY-100 or
BKHY-200)
1 sets
HY-100 can support one dental chair,HY-200 can support two dental chairs 1 sets
Read more

mlite

ME700 ME500
Light Quality Characteristics
Maximum light intensity 160,000 Lux 140,000 Lux
Beam Size Characteristics (measured at 1m)
Light Field Diameter (d10) 200-420mm 140-310mm
Light Field Diameter (d50) 160-280mm 70-155mm
Beam Uniformity (d50/d10 Rao) 0.6 0.5
Comfort Halo 2,000mm Non Applicable

 

ME700 ME500
Electrical & Mechanical Characteristics
Nominal Power Consumption 80W 60W
Radiant Energy      mW/m2.Lux <3.9 <3.9
IP Rang of Light Engine 54 54
LED Life > 60,000 Hours > 60,000 Hours

 

Part Number
ME700 mLite SLIM LED(160,000 Lux)
ME500 mLite SLIM LED(140,000 Lux)
ME700 mLite SLIM LED(160,000Lux) with emergency baery (upto 7 hours)mLite SLIM LED(140,000Lux) with emergency baery (upto 8 hours)
ME500
Read more

LABORATORY REFRIGERATOR MPR-E28

LABORATORY REFRIGERATOR MPR-E28

Technical Parameters:

Model no. MPR-E28
External Size(W*D*H) mm 620*575*1980
Capacity 298L
Temp. Range 2℃~8℃
Temp. Accuracy 0.1℃
Control System Microprocessor Control, Large Screen LED Display
Alarm Audible and visual alarm for High and low temperature, Power failure alarm, Door ajar, Thermostat failure
Refrigeration Type Forced air refrigeration system
Refrigerant R600a, CFC Free
Condenser & Evaporator Bundy tube condenser
Defrost Manual defrost Auto defrost
Construction
Structure
Internal Material
External Material
Unibody Design & Mono-assembly foaming (Rigid polyurethane
insulation material)
Embossed aluminum sheet
Spraying steel plate
Shelves 5 pcs
Door 189W
Power Supply AC220V+10%, 50/60Hz
Optional Accessory Temperature recorder,Temperature printer (USB port can not be selected at the same time ), probe access port
Package Size(W*D*H)mm 700*650*2030
Gross weight 84kg
Read more

MEDALLION 400

TECHNICAL SPECIFICATION

Tissue Monitoring Technology

The Tissue Monitoring technology monitors the tissue density, especially for polypectomy and papillotomy,
cutting is smarty dided incut and Pause so that coagulation occurs in each pause, The system is intelligent to change the pause interval as tissue density changes, hence producing fine cutting with a coagulation effect.

REM (Return Electrode Monitoring)

Return electrode contabg quality monitoring system (REM). the REM system continually monitors patient impedance levels and deactivates them.
Generator fa fault in the patién/retur electrode contacts detected, which minimizes the danger of bringing incidents.

Application

General surgery, Gastroenterology. Dermatology. Yasuciar surgery, Obstetrics & Gynecology, ORL/ENT surgery. Neurosurgery, Orthopedics and plastic surgery, and other open surgery

Waterproof Panel operation

Microcomputer Auto Control, Two zone (LED) digital display.

Compatible with other Equipments

Endoscopy. HV Argon Plasta Coagulator, Optimum smoke Evacuation System.

Standard Accessories

Foot switch 01pc Disposable pencil 02pc
Cable for ate patient plate 01pc Disposable patient plate 05pc
Bipolar forceps 01pc Power cable 01pc
Bipolar forceps cable 01pc user manual: 01pc

Max Output Power(W)

Mono pure cut : 400
Mono blend 1 250
Mono blend 2 150
Mono standard coag 120
Bipolar coag 70
Read more

TABLE TOP SMALL CAPACITY SHAKER MOS-A10

TABLETOP SMALL CAPACITY SHAKER MOS-A10

Features:

* Incoming call recovery function.
* Equipped with a high-quality servo motor, the control speed is accurate, the high and low-speed
performance is good, and the stability is strong.
* Ultra-low speed start function, adjustable start speed. The speed-up control circuit is adapted to start
slowly and accelerate steadily to ensure the safety of experimental samples.

Technical Parameters:

Model No. MOS-A10
Controller PID
Display LCD
Shaking Mode Rotatory shaking
Drive Mode Unishadri e
Rotating Speed 20-300rpm/min
Rotating Accuracy ±1rpm
Vibration Range φ26mm
Timing Range 0-9999h/min
Shaking Plate Size 460*380mm
Standard Capacity 250ml*16
Max. Capacity 100ml*22 or
(Flask clamp) 250ml*16or 500ml*8
Max. Capacity 100ml*20 or
Consumption 80W
Power Supply 220V±10%, 50/60HZ (Standard); 110V±10%, 60Hz

 

Read more