Patient Monitor MY-MP15

Medallion Equipments

 

Multi-Parameter Vital Sign Units:

Specifications and feature

  • 15.1” color TFT display & high resolution: 800×600dpi.
  • 6Standard Parameter ECG,Spo2,NIBP,RESP,TEMP,HR/PR
  • Real time ST segment analysis and ARR analysis.
  • SPO2 Pitch Tone Variation and Drug Dose Calculation.
  • Parameter waveform and characters color choice.
  • Standby mode for Energy saving and suspend monitoring.
  • 7lead ECG waveform display in phase.
  • Capturing dynamic waveform.
  • Built-in rechargeable lithium battery, and battery volume.

 

Optional parameter:

    • Thermal Recorder
    • touch screen
    • Etco2 mainstream and side stream
    • wall mount
    • trolley
Read more

Biosafety Cabinet

MCS-A42

Medallion Equipment’s UK

 

Technical Parameters:

 Model MSC-A42
External Size(W*D*H) 1383*775*2220mm
Internal Size(W*D*H) 1210*600*660mm
Work Surface Height 762mm
 Max Opening 470mm
Air Flow Volume Inflow                   462m3/h(272cfm)

Down Flow          65%:863m3/h(507cfm)

Exhaust                35%:462m3/h(272cfm)

Front Window Motorized. Two-layer laminated toughened glass>6mm. Anti UV
HEPA Filter Two, 99.9995% efficiency at 0.12µm, filter life indicator
 Inflow Velocity 0.53±0.025m/s
Downflow Velocity 0.33±0.025m/s
ULPA Filter Two, 99.9995% efficiency at0.12pm, filter life indicator
File Guard Type Aluminum alloy frame, Glass fiber filter paper
Noise NSF 49<=67dB
Illumination >=1000Lux
Display Color Touch Screen
Waterproof Socket Two, Total Consumption <=500W
Tap Water Tap*1, Glass Tap*1
Ground Resistance <=0.10Ჲ
Power Supply AC230V, 50/60Hz; AC115V, 60Hz, Full Load Amps:9A, BTU/Hr:1689
Consumption 500W
Alarm Abnormal airflow velocity, Filter replacement, Filter window at unsafe height, High filter pressure alarm.
Motor EC motor, 115V & 230V acceptable, speed adjustable, high efficiency and low power consumption.
Material Working area: 304 stainless steel

Frame and decorative plate: cold-rolled steel with anti-bacteria power coating

UV Lamp 30W

Germicidal UV lamp, Emission of 253.7 nanometers for most efficient decontamination

Illuminating Lamp 20W*2

LED Lamp

Standard Accessory LED lamp*2, UV lamp*2, Base stand, SS water tap*1, Drain valve

Waterproof sockets*2, Stainless steel IV Bar with 10 hooks, Remote control

Optional Accessory Armrest, Airflow tester, Formalin fumigation sterilizer, infrared sterilizer, Electric height adjustable base stand
Package size (W*D*H)mm 1540*1080*1900
Gross Weight(kg) 330

 

Read more

BIOLOGICAL SAFETY CABINET CLASS II B2

MSC-B1100

Medallion Equipment’s UK

Introduction:
The AC Series Class II B2 Biological Safety Cabinet is a high-performance containment unit
designed for laboratories handling hazardous biological materials and chemical compounds.
Unlike traditional Class II cabinets, the B2 model provides 100% total exhaust, ensuring that all
potentially harmful air is completely expelled from the laboratory, making it ideal for
applications requiring both biological and chemical safety.

Features:
1. Color key display: large screen, more clear and dynamic display of various values of the safety
cabinet, and has the function of appointment timing.
2. Automatically adjust the wind speed.
3. With power-off memory function, the state before power-off will be restored after power-on,
and there will be visual prompts and alarms.
4. The integrated design of the operation area makes it easy to disassemble and clean.
5. The cabinet is separated from the base. The height of the adjustable base can be customized.
6. Interlocking function: UV lamp and front window; UV lamp and fan, LED lamp; fan and front
window.
7. It has the function of appointment timing, which can automatically set the time of starting and
shutting down the safety cabinet and the running time of ultraviolet lamps, fans and sockets.
8. The front window closes the double trigger signal,so that the sterilization and disinfection
function of the ultraviolet lamp is normally turned on.
9. The negative pressure air duct is equipped with a foreign matter filtering structure to prevent
foreign matter such as paper scraps from entering the fan system and affecting the normal
operation of the product.
10. The front window glass has a one-key lift function.
11. The cabinet is designed with a 10° inclination angle, which is in line with ergonomic
principles, with a larger viewing angle, convenient operation and more humanization.
12. The one-piece hand rest has a large fat surface, which has a larger contact area with the arm
and is more comfortable.

Technical Parameters:

 Model MSC-B1100
 Max Opening 480mm
 Inflow Velocity 0.53±0.025m/s
Downflow Velocity 0.33±0.025m/s
ULPA Filter Two, 99.9995% efficiency at0.12pm, filter life indicator
Front Window Motorized. Two-layer laminated toughened glass>6mm. Anti UV
Noise <65dB
UV Lamp 30W*1

UV timer, UV life indicator, emission of 235.7 nanometers for most efficient decontamination

LED Lamp 12W*2
Illumination >1000Lux
Consumption 1300W
Waterproof Socket Two, total load of two sockets: 500W
Display LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc
Control System Microprocessor
Airflow System 0% air recirculation, 100% air exhaust
Visual and Audio Alarm Abnormal airflow velocity, Filter replacement, Front window at unsafe height, High filter pressure alarm, abnormal power failure
Material Work Zone: 304 stainless steel

Main Body: Cold-rolled steel with anti-bacteria powder coating

Work Surface Height 770mm(can be customized)
Caster Foot master caster
Power Supply AC220V, 50/60Hz; 110V, 60Hz
Standard Accessory LED lamp 2pcs, UV lamp 2pcs, Base stand. Remote control, Foot switch, Drain valve, Waterproof socket 2pcs, Exhaust blower, Exhaust duct
External Size(W*D*H) 1100*775*2250mm
Internal Size(W*D*H) 940*600*660mm
Tested Opening Safety height 200mm(8″)
Package Main Body Exhaust

Blower(W*D*H)

1230*990*1840mm
930*800*700mm

 

Read more

Water Distiller MLW-D10

Medallion Equipment’s UK

Features:

  • Stainless steel material, adopt stamping and welding technology.
  • Water shortage and power-off alarm; automatically make up water and heat again.
  • Power, heating indicator and show water shortage.

 

Technical Parameters:

Model no. MLW-D10
Water Output >10L/H
Consumption 7.5KW
Power Supply 380V/50HZ
External Size(Dia.*H) 235*855mm
Package Size(W*D*H) 360*360*920mm
Gross Weight 9.5kg

 

 

Read more

Automatic Hematology Analyzer MHA-70

Medallion Equipment’s UK

Automatic hematology analyzer

  • Very compact 5 part DIFF instrument with CRP measurement
  • Constant speed with 72 samples/hour
  • 27 report parameters, 10 research parameters, 2 scattergrams and 2 histograms
  • Whole blood, micro-whole blood, pre-diluted blood
  • CBC+DIFF+CRP, CBC+DIFF, CRP, CBC, CBC+CRP
  • Build-in reagents position and 10.4 inch touch screen bring the many advantages to the smaller volume laboratory
  • Minimum 30 pL of blood, complete the CBC+DIFF+CRP in one minute
  • 360° rotate the tube automatically to avoid barcode scanning errors
  • CRP reagent stored on-board at 2-8 °C, even after equipment shutdown
  • Multi-function USB extension to connect printer, scanner, mouse, data export, etc
  • Bi-directional LIS, improve work efficiency and convenient data transfer

Unique Comprehensive Clinical Information

  • “5-Part WBC differentiation + CRP, 37 parameters
  • “2 scattergrams, 2 histograms
  • “FR-CRP with linearity of 0.2-320mg/L
  • Excellent performance
  • “72Test/Hour
  • “Only 30 pi sample volume for CBC + DIFF +CRP measurement
  • “Individual CRP mode
  • “The CRP reagent is stored on-board at a constant temperature of 2-8 C, even after equipment shutdown, in order to guarantee result stability

Full Traceability System

  • Original instrument, reagent, QC&Cali to present the quality tracing and traceability system

Affordable for Your Choice

  • Low cost for real benefits
  • Little reagent consumption

Perfect QC Function

  • L-J, X-B, X-R
  • 3 levels of controls for daily QC with Levey-Jennings charts

User-friendly Design

  • Compact design
  • High resolution 10.4 inch touch screen
  • Multi-language operating interface
  • Large storage capacity up to 200,000 samples
  • Closed tube for STAT samples
  • Rotate the tube automatically to avoid barcode scanning error
  • Reagents could be stored in the instrument to save space

Flexible Option

  • Auto-loader and CRP module are optional

Technical Parameters:

Reportable Parameters

 

27: WBC, BASO#, NEUT#, EOS#, LYM#,

MON#, BASO%, NEUT%, EOS%, LYM%,
MON%, RBC, HGB. MCV, MCH, MCHC,
RDW-CV, RDW-SD, HCT, PLT, MPV, PDW,

PCT, P-LCR, P-LCC, HS-CRP, FR-CRP

Research Parameters 10: Blast#, Blast%, ALM#, ALM%, IMM#,
IMM%, Left#, Left%, NRBC#, NRBC%
Scat tergrams 2
Histograms 2
Semiconductor laser flow
cytometry+Cytochemical
staining+Impedance method for WBC
differential
Test Principle Cyanide-free colorimetry for hemoglobin test,
Impedance method for RBC and PLT
counting, Latex Immunoturbidimetric Method
for CRP test
Throughput CBC+DIFF: 60 samples per hour, CBC+DIFF
+ CRP: 60 samples per hour, CRP: 60 samples per hour
Sample mode Whole blood mode,
Micro-WB mode,
Pre-dilute mode
Sampling type Manual or automated sampling (Auto-loader is optional)
Data Storage Capacity At least 200,000 results

 

Data system

 

RJ45 network interface, USB interface,

Support bi-directional LIS

Power consumption 21OVA
Dimensions (DxWxH) 681mmx556mm><532mm (with auto-loader),
520mmx380mmx532mm (without auto-loader)
Weight 51kg (with auto-loader), 43kg (without auto loader)

 

Read more

M23C-MII

Suction Machine

M23C-MII

Features

  1. Imported diaphragm pump oil free pump mechanism.
  2. Low noise and maintenancefree
  3. All ABS plastic shell
  4. Bottle is easy for cleaning and disinfection
  5. With overflow protection unit to prevent liquid from getting into pump body
  6. Used for operations and wards for taking out puts, blood, sputum and other thick liquid from human body.
  7. Vacuum continuously adjustable
  8. Triple or over flow safety device.
  9. Change over valve
  10. Suction tubing of silicone with coupling connection for each jar
  11. Piston or Diaphragm type with Heavy duty Mobile Suction Unit with twin jars (Polysulfide or Polycarbonate type) of capacity up to 4 or 5 liter each, Autoclavable.

Technical Specifications:

PARAMETER SPECIFICATION
Power Voltage AC 220V±10%, 50Hz±2%
Aspiration rates 40-60 liters/minutes at 640-900mm
Suction Rate >40L/min
Negative Pressure Range 0.013-0.09Mpa (680mmHg)
Suction Bottle 2000mlx2 (plastic bottle)
Input Power 400VA
Noise <50dB

Accessories

  • 100 x Hydrophobic/bacterial filter
    Trolley with lockable wheels.
Read more

MV-M70

Ventilator

MV-M70

ICU VENTILLATOR:

  • MVM70 is a critical care ventilator suitable for intrahospital transport and subacute care of infants, children and adults. It combines the advantages of a flexible noninvasive ventilator with a fullfeatured invasive ventilator.
  • Microprocessor controlled powerful ventilation system mounted on trolley or pendant. In case of pendant mounted, trolley is also required for compressor placement.
  • It has comprehensive functionality and a userfriendly design. MVM70’s internal turbine provides needed air pressure with a low sound level and, along with its internal batteries, prepare it fully for mobile use.
  • Microprocessor controlled powerful ventilation system mounted on trolley or pendant. In case of pendant mounted, trolley is also required for compressor placement.
  • Colortouchscreenl5’,MinimumLCDorTFTorbetter.
  • PatientRange:AdultandPediatrics.
  • Breathing classification: Pressure control, Volume control Pressure control with set Volume Breath.

Patient Type

  • Adult, Child (>3 Kg)
  • Tidal volume (Vt) 502000 mL (Adult) 20300 mL (Child)

MODESOFVENTILATION:

  • Volume control.
  • Assisted CMV.
  • Pressure control PC.
  • Assist Pressure Control.
  • CPAP.
  • SIMV with VC.
  • SIMV with PC.
  • Pressure support.
  • BiPAP ventilation.APRV or equivalent
  • Non invasive ventilation(NIV) with PC, SIMV and PS.
  • Highflow02Therapy.

Monitoring parameters for set and measured values imultaneously:

  • Backup ventilation.
  • Microprocessor gas delivery system.
  • Breath circuit Compliance Compensation.
  • Expiratory hold or Inspiratory hold.
  • Pressure or Volume or flow trigger sensitivity.
  • Spon Triggered breaths should be indicating in pressure or volume curve.
  • Trend Data of 72hoursormore.
  • Total breath rate.
  • Oxygen concentration Fi02(Through Paramagnetic Ensor technology or Non consumable sensor).
  • Expired minute volume.
  • Peak Pressure.
  • Mean pressure.
  • Lung Mechanics with pressure and volume loops.
Read more

ECG-M-3

ECG MACHINE

ECG-M-3

Features

  • 7-inch-high resolution color touch screen
  • 12-lead simultaneous acquisition and display
  • ECG Automatic measurement and interpretation function
  • Complete digital filters, resisting baseline drift, AC and EMG interference
  • Compact and lightweight design
  • Support USB flash disk and micro-SD card to extend memory
  • Software upgrade via USB/SD card
  • Built-in rechargeable Li-ion battery
  • Manual & Automatic Operation
  • Variable Gain: 1/2, 1, 2 cm / mV
  • Interpretation Software
  • Recording Trace Speed: 10 / 12.5, 25 and 50 mm / sec
  • Muscle artifact and AC (50 Hz) interference filters
  • Defibrillator Protection
  • Built-in battery operation with 60 mins backup or better
  • Noise Filter and Baseline Correction
  • Thermal Recorder for printing out of Three Channels simultaneously
  • Paper Rolls / Z Folds / Recording Papers: Quantity = 10 (Each Roll Length minimum 20 meters)
  • Operating Requirement: AC 220 V & 50 Hz
  • Securing / fixation to the mobile Cart by strap or other means must be provided

Technical Specifications

 

PARAMETER SPECIFICATION
Lead Standard 12 leads
Single Package Size 32*25*17cm
Single Gross Weight 2.8 KG
Acquisition Mode Simultaneous 12 leads acquisition
total gross weight 22 KG
Measurement Range ±5mVpp
Input circuit Floating; Protection circuit against Defibrillator effect
Input Impedance >50MQ
Input circuit current <0.05µA
Record mode Automatic: 3CHx4+lR, 3CHx4, 3CHx2+2CHx3,3CHx2+2CHx3+lR,6CHX2;

 

Read more

MCM-E8000

Cardiac monitor with accessories

MCM-E8000

Features

  1. 12-inch, two kinds of configuration for choice: 4 Para, or 6 Para

4 Para: NIBP, SPO2, PR, TEMP

6 Para: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR

  1. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
  2. Efficient resistance to interference of defibrillator and electrosurgical cautery;
  3. SPO2 can testing for 0.2% Weak;
  4. RA-LL impedance Respiration;
  5. Trend Coexist Display;
  6. OxyCRG DyNamic View Display;
  7. Options of Central Monitoring System;
  8. Built-in rechargeable battery 2200mAh;
  9. 8″ high resolution color TFT LCD display;
  10. Large volume of tabular and graphic trends information storage and easy to recall;
  11. Anti- defibrillator; Optional Anti-ESU

Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

 

Heart Rate and Alarm

Range

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great

Resolution: 1 bpm

Sensitivity: > 200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: < 10 uA

Baseline Recovery: < 3 S after Defi.

ECG Signal Range: ±8 m V (Vp-p)

Bandwidth

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

 

Respiration

Method: Impedance between R-F (RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range: 0.3~5.0Ω

Base line Impedance Range: 0 – 2.5 KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Measuring Range:

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm

Resp. Alarm Range:

-High alarm range limit: 8~120 rpm

-Low alarm range limit: 6~120 rpm

Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

 

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range

Adult Mode

-SYS: 40 ~ 270 mmHg

-DIA: 10 ~ 215 mmHg

-MEAN: 20 ~ 235 mmHg

Pediatric Mode

-SYS: 40 ~ 200 mmHg

-DIA: 10 ~ 150 mmHg

-MEAN: 20 ~ 165 mmHg

Neonatal Mode

-SYS: 40 ~ 135 mmHg

-DIA: 10 ~ 100 mmHg

-MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

-Adult Mode: 297±3 mmHg

-Pediatric Mode: 240±3 mmHg

-Neonatal Mode: 147±3 mmHg

 

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy: ±2bpm

 

Temperature

Channel: 2

Measuring and Alarm Range: 0 ~ 50 °C

Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec.

Average Time Constant:<10 Sec.

 

Standard Packing List

4 Para

Adult finger SpO2 sensor

Adult NIBP cuff

NIBP extension tube

TEMP sensor

AC power adaptor

Operation instruction

 

6 Para

5-lead ECG cable (including RESP)

Adult finger SpO2 sensor

Adult NIBP cuff

NIBP extension tube

TEMP sensor

AC power adaptor

ECG electrodes

Operation instruction

 

Optional Function

Central Monitoring System

Read more