MBK-63

FULLY AUTOMATED HEMATOLOGY ANALYZER

MBK-63

 

Features:

  • Throughput 60T/H.
  • 14 inch touch screen.
  • Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting.
  • 3D holographic scattergram displays the accurate 5 part differentiation of WBC.
  • Large storage capacity:  100,000 results(including histogram, scattergram, patient information).

 

Parameters:

Model MBK-63
Throughput 60Tests/hour
Assay Items 5 parts, 29 parameters,3 histograms
Principle Tri-angle laser scatter,Flow cytometry method, 3D scattergram analysis, Impedance  methodfor RBC and PLT counting, Cyanide-free method for HGB test
Test Mode CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted.
Parameters WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#

4 Research parameter: ALY%, ALY#, IG%, IG#

Performance Item Linearity range Carry Over CV
WBC (0~300.0×10^9)/L ≤0.5% ≤2.0%
RBC (0~8.00×10^12)/L ≤0.5% ≤1.5%
HGB (0~250)g/L ≤0.5% ≤1.5%
PLT (0~3000×10^9)/L ≤1.0% ≤4.0%
Sample Volume CBC+DIFF mode≤20μl   CBC mode≤10μl
Storage 10,000 results including histograms, scattergrams and patient information
Interface 4 USB ports, 1LAN port Bi-direction LIS, support HL7 protocol,Internal RFID reader
Power Supply AC220V±10% 50/60Hz; 110V±10% 60Hz; 400VA
Package Size 670*590*790mm(W*D*H)
Gross Weight 53kg
ReagentPackage Size 320*320*290mm (W*D*H)
ReagentGross Weight 22kg
Read more

MPE-B20

Plasma Extractor

MPE-B20

Medallion Equipments UK

 

Introduction:

Plasma Extractor is designed to extract blood component from centrifuged bags. It is widely used in hospital, blood station, etc. After the plasma of blood bags is layered, the pressure of plasma-separating clip enables different components of blood to be extruded from top to bottom.

Features:

  1. Manual system
  2. Easy to observe the separation of the plasma and red blood cells
  3. Programmable
  4. Digital display of programmed speed, timing, braking Self-diagnostic with error display
  5. Over temperature alarm
  6. Rotor Rpm calibration window

Technical Specifications:

Model MPE-B20
Clamping Force 20N
Applicable Blood Bag 100ml, 200ml, 300ml, 400ml
Material Stainless steel
External Size (W*D*H) 165*250*250 mm
Package Size (W*D*H) 310*310*240mm
Net Weight 2.5kg
Gross Weight 2.8kg

 

Read more

FULLY AUTOMATED COAGULATION ANALYZER

MAC-M50

 

Features:

-Random Access, smart and compact

-Clotting, Chromogenic, Immunologic measuring methods

-User friendly touchscreen interface, simple & easy to operate

-High throughput routine assays

-Labor saving, simple programming and real walk-away system

-Reagent open system, close system on request

-Multi – language software (optional)

 

System Function

  • Throughput: 60 tests/hour for PT, 50 tests/hour for PT and APTT
  • Parameters: PT, APTT, TT, FIB, AT-III, PLG, D-Dimer, FDP, etc.
  • Measuring methods:
  • Clotting: Scattered Light Detection method
  • Chromogenic: Colorimetric method, 405nm
  • Immunologic: Turbidimetric method, 575nm
  • Memory: 100,000 test results and 10,000 reaction curves
  • Quality control: 12 QC File*10 test items*30 curve* 12 month
  • Calibration: 6 points*10 items
  • Automatic, Random Access
  • STAT sample priority
  • Auto re-diluent/ re-test
  • Barcode-reading support (optional)

 

Sample Tray

  • Sample tray: 27 positions, user-defined STAT
  • Incubation temperature: 37±0.5 °C

 

Reagent Tray

  • Reagent tray: 23 positions
  • Reagent cooling: ≤16 °C
  • Query successful

 

Reaction Tray

  • Cuvettes on board: 72
  • Min reaction volume: 150 µl
  • Reaction temperature: 37±0.5 °C

 

Probe

  • With probe pre-heating
  • Automatic washing both inside and outside
  • With collision protection, liquid level detection, and inventory checking

 

Print out

  • Built-in thermal printer, external printer optional

 

Measuring and Optic System

  • Light: LED
  • Power: AC 110/240V, 50-60±1Hz
  • Temperature: 10 °C-30 °C, humidity ≤85%
  • Water consumption: <0.5 L/hour
  • Dimension L×W×H (mm): 660×580×510
  • Weight: 53 KG
Read more

Automatic Blood Coagulation Analyzer MCA-1000

Automatic Blood Coagulation Analyzer

MCA-1000 Automatic Blood Coagulation Analyzer is a new generation of fully automatic coagulation analyzer, providing reliable results to meet the requirement of laboratory for thrombus and homeostasis testing.

Features

High efficiency, PT: 150 samples/hour
Random access of clotting, chromomeric substrate, immunoturbidimetric assay, fully meeting the needs of laboratory routine and special testing
Small in size, aesthetic in appearance and multiple in function, low water consumption, and environmental economy.
Fully automated bench top equipment
Simultaneous PT & APTT tests/hour: able to perform >100 tests/hour
Method used for clotting assay is photo-optical /Transmittance / Light Scatter
Instrument should facilitate both immunologic and chromogenic assay
Instrument should have cap piercing technology
Instrument should have capability at least 5 dedicated stat sample positions for performing emergency sample
Instrument is capability to handle low volume sample
Instrument is able to perform platelet aggregometry test with ADP, Epinephrine, Collagen, Arachidonic Acid, Ristocetin & fibrinogen, D-Dimer, Thrombin time, factor assay, VWF antigen and activity, RiCOF, Lupus Anticoagulant, Ant thrombin-III, Protein S and C, Plasmin and Plasminogin
Instrument should have flagging for abnormal value
Instrument has multi wave detection system, wave form analysis & perform inhibitor studies along with automated mixing tests
Instrument has an on-board consumables (Cuvette, cleaning solution etc.) loading option without interrupting instrument operation , 500 cuvette on-board capacit , liquid level detection feature for reagents
Storage capacity is 10,000 sample results with their reaction curves

Technical Parameters:

Category Specification
Throughput PT: 100 samples/hour
Test Methods Clotting assay, chromogenic substrate assay,

immunoturbidimetric assay

Analysis System 8 positions, 8 positions, 72 positions
QC Real-time QC, daily QC and inter-day QC with multi-concentration method
Sample Volume 5µL – 170µL
Sample Position 40 positions
Reagent System
Reagent Volume 20µL – 175µL
Reagent Position 20 refrigerated reagent positions, 3 normal-temperature reagent positions
Storage Temperature of Reagent ≤ 16°C
Port Network port
Connection with LIS/HIS system Bi-directional
Power Consumption 450VA
Power Supply 220/230V, 50/60Hz
Outline Dimensions 660mm x 475mm x 554mm (LxWxH)
Weight 75kg
Advanced Detection Principle Optical transmission principle
Integrated Reagent Management 16°C reagent storage
Barcode scanning for reagent recognition1ml, 50ml available for various tests, Calculate remaining volume and test numbers
Flexible Sample Management Supports original standard tubes and sample cups
Automatic barcode scanning for sample identification
Accurate Temperature Control Temperature control system regulates incubation and reaction temperature accurately
Friendly Operation Interface Convenient operation system
Abnormal sample can be diluted and re-run automatically
PT-derived and CLAUSS method for FIB item are available
Reliable Test Results Globally imported stable and long lifespan main parts, probe & lamp LED, etc. 1
 Data management

Quality System Compliance:

 COUNTRY OF MANUFACTURER

 Warranty:

PC based with latest window LCD Monitor with hard disk 500GB and at least with 2 USB port and must be compatible with the instrument &UPS with a backup of 30 minutes or more

 

ISO, CE certified & FDA Approve

Two (02) years comprehensive warranty.

User manual and Service manual

Read more