MPM-12L (Cardiac Monitor Wall Mounted)
Cardiac Monitor Wall Mounted
MPM-12L
Features
- The monitor adopts Ergonomic design and a compact structure to meet the needs of various parameter detections. It is suitable for adults, children, and newborns.
- Standard parameters: SpO2, 3/5 leads ECG, PR, HR, RESP, NIBP, 2*TEMP.
- Optional parameters: EtCO2, 12 leads ECG, 2*IBP.
- 12 inch color LCD screen with optional touch screen and rotator knob.
- Capable to visualize 6 or more waveform. Support color coding for different waveform.
- 28 ST segment analysis with ST trend with continuous display of ST value on screen.
- Multiple screen layout to view big font size in numeric and waveform.
- Trending facilities for up to 360 hours of both graphical & numerical along with event review facility for all parameters and full waveform disclosure facility.
- Different visual alarm with color coding and audible alarms for various parameters with three levels of volume adjustment.
- Support HL7 protocol to access the central monitoring system, low-power design, extending battery life Configure, fanless design to ensure a quieter and cleaner environment Arrhythmia detection and analysis in various leads.
- Standard application: 5-leads ECG, NIBP, SpO2, RESP, TEMP, PR/HR
- Optional application: Touch screen, IBP, EtCO2 (mainstream/sidestream), 12-lead ECG, recorder, CMS
- Large font, dynamic short trend display interface, calculation of hemodynamics and cardiac output.
Specifications
Display
Size: 12 inches Color TFT LCD
Resolution: 1024*768 pixels
ECG
3-lead: I, II, III
5-lead: I, II, III, aVR, aVL, aVF, V
ECG Range: 0~100%
ECG Resolution: 2.36uV/LSB
HR Range: 15~300bpm(adult), 15~250bpm(pediatric/neonate)
HR Accuracy: ±1 bpm or ±1%, whichever is greater.
RR Range: 0~120bpm
RR Accuracy: 15~120rpm: ±2rpm or ±2% <15rpm: Undefined
Sweep speed: 6.25 mm/s, 12.5mm/s, 25mm/s, 50mm/s, less than ±5% error
Display sensitivity: 2.5 mm/mV (X0.25), 5 mm/mV (X0.5), 10 mm/mV (X1), 20 mm/mV (X2), 40 mm/mV (X4), Auto, less than ±5% error
SPO2
SPO2 Measurement Range: 0~100%
SPO2 Accuracy: 70 to 100%: ±2% (adult/pediatric, without motion)
70 to 100%: ±3% (neonate, without motion)
0 to 69%: Not specified.
PI Range: 0~20%
PR Range: 25-250bpm
PR Accuracy: ±2bpm or ±2% (whichever is greater)
TEMP
Technique: Thermal resistance
Measurement Range: 0~50.0℃
Accuracy: ±0.2°C
Resolution: 0.1°C
Refresh Rate: 1s
Alarm limit range: Temp High: (low limit +0.1℃) ~ 50.0℃
Temp Low: 0℃ ~ (high limit -0.1℃)
NIBP
Measure method: Automatic oscillation method
Pressure Range: 0~300mmHg (0~40kPa)
Pressure Accuracy: ±2mmHg or ±1% of reading (whichever is greater)
Resolution: 1mmHg or 0.1kPa
SYS Range: Adult: 40-270mmHg
Pediatric: 40-200mmHg
Neonate: 40-130mmHg
DIA Range: Adult: 10-210mmHg
Pediatric: 10-162mmHg
Neonate: 10-90mmHg
Mean Range: Adult: 20-230mmHg
Pediatric: 20-170mmHg
Neonate: 20-100mmHg
Accuracy: mean deviation<±5mmHg, standard deviation<8mmHg
Work pattern: manual, automatic, continuous measurement
Automatic mode measurement interval: 1min/ 2min/ 3min/ 4min/ 5min/ 10min/ 15min/ 30min/ 60min/ 90min/ 2h/ 3h
Continuous mode measurement time: 5 min
Maximum single measurement time: 180s
Respiration
Technique: Trans-thoracic impedance
Lead: Options are lead I and II
Respiration excitation waveform: <300µA RMS, 62.8kHz (±0%)
Respiration impedance range: 0.3~5Ω
Baseline impedance range: 200~2500Ω (using an ECG cable with 1kΩ resistance)
Bandwidth: 0.2~2Hz (-3 dB)
Sweep speed: 6.25 mm/s, 12.5mm/s, 25mm/s, 50mm/s
PR
Measurement range: 25bpm~250bpm
Resolution: 1bpm
Alarm limit: PR High: (PR Low limit +1bpm) ~ 300bpm
PR Low: 15bpm ~ (PR High limit -1bpm)
HR
Measurement range: 15~300bpm (adult)
15~350bpm (pediatric/neonate)
Resolution: 1bpm
Accuracy: ±1 bpm or ±1%, whichever is greater
Sensitivity: 0.2mV
Data Storage
Trends: A minimum of 120 hours trend data with the resolution no less than 1 minute
Events: 200 events
NIBP measurements: 200 events
Interpretation of resting 12-lead ECG results: 20 sets
IBP (Optional)
Number of channels: 2
Pressure Range: -50~350mmHg (-6.7~40.0kPa)
Accuracy: ±2% or ±1 mmHg, whichever is greater (excluding sensor error)
Resolution: 1 mmHg (0.1kPa)
Refresh Rate: 1s
Sensitivity: 5μV/V/mmHg
Zero adjustment range: ±200 mmHg
Impedance range: 300~3000Ω
Volume displacement: <0.04mm³/100mmHg
EtCO2 (Optional)
Measurement mode: Sidestream, Mainstream
Technique: Infrared absorption
Zero RR delay: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
CO2 Range: 0~20.0 vol%
CO2 Accuracy: 0~12 vol%: ± (0.2 vol%+2% of readings)
12~20 vol%: ± (0.2 vol%+6% of readings)
AwRR Measurement Range: 0~150rpm
Resolution: 1 rpm
AwRR Accuracy: Mainstream: 0~150rpm, ±1rpm
Sidestream: 0~69rpm, ±1rpm; 70~150rpm, Undefined
Alarm limit: EtCO2 High: (EtCO2 Low limit +1mmHg) ~ 150mmHg
EtCO2 Low: 0 ~ (EtCO2 High limit -1mmHg)
FiCO2 High: 0 ~ 150mmHg
AwRR High: (AwRR Low limit +1 rpm) ~ 120rpm
AwRR Low: 0 ~ (AwRR High limit -1 rpm)
Mounting:
Wall-mount bracket/shelf (local or imported) included
Included Accessories:
All reusable sensors, probes, and cables required for adult and pediatric monitoring of all listed parameters