HPLC-MK-100

Medallion Equipments UK

Features:

  1. The system offers a comprehensive and flexible isocratic mode, and a binary gradient system is also available. Detection capabilities include DAD, UV/Vis, FL, RI and ELSD.
  2. The new optional, solvent manager units can easily switch 4 to 8 kinds of solvent base on binary gradient system. There are several configurations available for user selection.
  3. The real-time solvent pressure compensation control enhances detection precision. The integrated check valve ensures stable fluid delivery and simplifies maintenance.

 

HP High-Pressure Constant Flow Pump:

Liquid Infusion System Dual-piston reciprocating parallel pump, equipped with a binary high-pressure mixer
Flow Rate Range 0.001~10ml/min
Max Output Pressure 42MPa
Flow Accuracy ≤±1%
Flow Precision RSD<0.07%
Qualitative Repeatability RSD6≤0.1%(naphthalene/methanol standards)
Quantitative Repeatability RSD6≤0.3%(naphthalene/methanol standards)
Pressure Fluctuation 0.1MPa
Power Supply AC220/110V, 50/60Hz

 

UV Detector:

Flow Cell Volume 8.0μl
Light Source D2 lamp
Wavelength Range 190~680nm
Spectrum Bandwidth 8nm
Wavelength Accuracy ±1nm
Wavelength Precision Below 0.1nm
Noise ≤0.25×10⁻⁵AU(static)/±1×10⁻⁵AU(dynamic, under given conditions)
Drift ≤0.4×10⁻³AU/h(static)/≤2×10⁻³AU/h(dynamic, under given conditions)
Minimum Detectable Concentration 3×10⁻⁹g/ml(naphthalene/methanol solution)

 

PDA Detector:

Wavelength Range 200~900nm(200~600*), Above 600nm just for W lamp
Arrays 512
Spectrum Bandwidth 10nm
Light Source D2 lamp+W lamp
Noise ±5*10⁻⁵AU
Sample Rate Max100Hz
Interface LAN, USB, R232

 

 

Auto-sampler:

Sample Loading Standard tray (1) 2ml*54 vials(default standard configuration)

Expanded tray (2) 10ml*15 vials (3) 4ml*35 vials

Each side could be set with one of the tray types and the tray in one side could be different from the other side; the system could automatically identify the tray type; maximum 108 vials are available (2ml vial)

Vial Height H≤52mm (including septa and cap-mat)
Metering Pump Volume 200μl (precision: 0.1μl)
Injection Mode Full loop injection

Partial loop injection

No waste injection

Automatic Protection Vial-missing alarm, sample needle fault alarm, pipeline jammed alarm, and leakage alarm
Power Supply AC115~230V, 50/60Hz
System Test Quantitative Repeatability Full loop injection: RSD6≤0.3%

Partial loop injection: RSD6≤0.5% (injection volume ≥ 10μl)

No waste injection: RSD6≤1.0% (injection volume ≥ 10μl)

Memory Effect ≤0.005% (designated washing procedure)
Maximum Pressure 40Mpa(conventional) 69Mpa (ultra-high-performance system)

 

Technical Parameters:

Model HPLC-MK-100
Software With Audit Trail /
Diode Array Detector /
High-pressure Constant Flow Pump MLC-100 HP*1
UV Detector
LC-100 UV
Yes
Diode Array Detector (With English Workstation) /
Workstation LC-100 WS Yes
Workstation EX-Clarity C50 /
Manual Sampler 7725i Yes
C18 5μm ID4.6*250mm Yes
High-precision Mixer EX1600 MX3 /
Power Supply AC220/110V, 50/60Hz
Optional Accessory UV detector, Rl detector, DAD100 detector, ELSD detector, FLD100 detector, column, column oven, ARCUS 5 auto-sampler
Package Size(W*D*H) 450*620*350mm*2
Gross Weight 34kg