HPLC
HPLC
HPLC-MK-100
Medallion Equipments UK
Features:
- The system offers a comprehensive and flexible isocratic mode, and a binary gradient system is also available. Detection capabilities include DAD, UV/Vis, FL, RI and ELSD.
- The new optional, solvent manager units can easily switch 4 to 8 kinds of solvent base on binary gradient system. There are several configurations available for user selection.
- The real-time solvent pressure compensation control enhances detection precision. The integrated check valve ensures stable fluid delivery and simplifies maintenance.
HP High-Pressure Constant Flow Pump:
| Liquid Infusion System | Dual-piston reciprocating parallel pump, equipped with a binary high-pressure mixer |
| Flow Rate Range | 0.001~10ml/min |
| Max Output Pressure | 42MPa |
| Flow Accuracy | ≤±1% |
| Flow Precision | RSD<0.07% |
| Qualitative Repeatability | RSD6≤0.1%(naphthalene/methanol standards) |
| Quantitative Repeatability | RSD6≤0.3%(naphthalene/methanol standards) |
| Pressure Fluctuation | 0.1MPa |
| Power Supply | AC220/110V, 50/60Hz |
UV Detector:
| Flow Cell Volume | 8.0μl |
| Light Source | D2 lamp |
| Wavelength Range | 190~680nm |
| Spectrum Bandwidth | 8nm |
| Wavelength Accuracy | ±1nm |
| Wavelength Precision | Below 0.1nm |
| Noise | ≤0.25×10⁻⁵AU(static)/±1×10⁻⁵AU(dynamic, under given conditions) |
| Drift | ≤0.4×10⁻³AU/h(static)/≤2×10⁻³AU/h(dynamic, under given conditions) |
| Minimum Detectable Concentration | 3×10⁻⁹g/ml(naphthalene/methanol solution) |
PDA Detector:
| Wavelength Range | 200~900nm(200~600*), Above 600nm just for W lamp |
| Arrays | 512 |
| Spectrum Bandwidth | 10nm |
| Light Source | D2 lamp+W lamp |
| Noise | ±5*10⁻⁵AU |
| Sample Rate | Max100Hz |
| Interface | LAN, USB, R232 |
Auto-sampler:
| Sample Loading | Standard tray (1) 2ml*54 vials(default standard configuration)
Expanded tray (2) 10ml*15 vials (3) 4ml*35 vials Each side could be set with one of the tray types and the tray in one side could be different from the other side; the system could automatically identify the tray type; maximum 108 vials are available (2ml vial) |
| Vial Height | H≤52mm (including septa and cap-mat) |
| Metering Pump Volume | 200μl (precision: 0.1μl) |
| Injection Mode | Full loop injection
Partial loop injection No waste injection |
| Automatic Protection | Vial-missing alarm, sample needle fault alarm, pipeline jammed alarm, and leakage alarm |
| Power Supply | AC115~230V, 50/60Hz |
| System Test Quantitative Repeatability | Full loop injection: RSD6≤0.3%
Partial loop injection: RSD6≤0.5% (injection volume ≥ 10μl) No waste injection: RSD6≤1.0% (injection volume ≥ 10μl) |
| Memory Effect | ≤0.005% (designated washing procedure) |
| Maximum Pressure | 40Mpa(conventional) 69Mpa (ultra-high-performance system) |
Technical Parameters:
| Model | HPLC-MK-100 |
| Software With Audit Trail | / |
| Diode Array Detector | / |
| High-pressure Constant Flow Pump | MLC-100 HP*1 |
| UV Detector LC-100 UV |
Yes |
| Diode Array Detector (With English Workstation) | / |
| Workstation LC-100 WS | Yes |
| Workstation EX-Clarity C50 | / |
| Manual Sampler 7725i | Yes |
| C18 5μm ID4.6*250mm | Yes |
| High-precision Mixer EX1600 MX3 | / |
| Power Supply | AC220/110V, 50/60Hz |
| Optional Accessory | UV detector, Rl detector, DAD100 detector, ELSD detector, FLD100 detector, column, column oven, ARCUS 5 auto-sampler |
| Package Size(W*D*H) | 450*620*350mm*2 |
| Gross Weight | 34kg |
MPR-E20