Automatic Hematology Analyzer MHA-70
Medallion Equipment’s UK
Automatic hematology analyzer
- Very compact 5 part DIFF instrument with CRP measurement
- Constant speed with 72 samples/hour
- 27 report parameters, 10 research parameters, 2 scattergrams and 2 histograms
- Whole blood, micro-whole blood, pre-diluted blood
- CBC+DIFF+CRP, CBC+DIFF, CRP, CBC, CBC+CRP
- Build-in reagents position and 10.4 inch touch screen bring the many advantages to the smaller volume laboratory
- Minimum 30 pL of blood, complete the CBC+DIFF+CRP in one minute
- 360° rotate the tube automatically to avoid barcode scanning errors
- CRP reagent stored on-board at 2-8 °C, even after equipment shutdown
- Multi-function USB extension to connect printer, scanner, mouse, data export, etc
- Bi-directional LIS, improve work efficiency and convenient data transfer
Unique Comprehensive Clinical Information
- “5-Part WBC differentiation + CRP, 37 parameters
- “2 scattergrams, 2 histograms
- “FR-CRP with linearity of 0.2-320mg/L
- Excellent performance
- “72Test/Hour
- “Only 30 pi sample volume for CBC + DIFF +CRP measurement
- “Individual CRP mode
- “The CRP reagent is stored on-board at a constant temperature of 2-8 C, even after equipment shutdown, in order to guarantee result stability
Full Traceability System
- Original instrument, reagent, QC&Cali to present the quality tracing and traceability system
Affordable for Your Choice
- Low cost for real benefits
- Little reagent consumption
Perfect QC Function
- L-J, X-B, X-R
- 3 levels of controls for daily QC with Levey-Jennings charts
User-friendly Design
- Compact design
- High resolution 10.4 inch touch screen
- Multi-language operating interface
- Large storage capacity up to 200,000 samples
- Closed tube for STAT samples
- Rotate the tube automatically to avoid barcode scanning error
- Reagents could be stored in the instrument to save space
Flexible Option
- Auto-loader and CRP module are optional
Technical Parameters:
| Reportable Parameters
|
27: WBC, BASO#, NEUT#, EOS#, LYM#,
PCT, P-LCR, P-LCC, HS-CRP, FR-CRP |
|
| Research Parameters | 10: Blast#, Blast%, ALM#, ALM%, IMM#, IMM%, Left#, Left%, NRBC#, NRBC% |
|
| Scat tergrams | 2 | |
| Histograms | 2 | |
| Semiconductor laser flow cytometry+Cytochemical staining+Impedance method for WBC differential |
||
| Test Principle | Cyanide-free colorimetry for hemoglobin test, Impedance method for RBC and PLT counting, Latex Immunoturbidimetric Method for CRP test |
|
| Throughput | CBC+DIFF: 60 samples per hour, CBC+DIFF + CRP: 60 samples per hour, CRP: 60 samples per hour |
|
| Sample mode | Whole blood mode, Micro-WB mode, Pre-dilute mode |
|
| Sampling type | Manual or automated sampling (Auto-loader is optional) | |
| Data Storage Capacity | At least 200,000 results
|
|
| Data system
|
RJ45 network interface, USB interface,
Support bi-directional LIS |
|
| Power consumption | 21OVA | |
| Dimensions (DxWxH) | 681mmx556mm><532mm (with auto-loader), 520mmx380mmx532mm (without auto-loader) |
|
| Weight | 51kg (with auto-loader), 43kg (without auto loader) |
M23C-MII