Portable Multi parameter Water Quality Meter MPH-900
Features:
PH:
*Multiparameter water quality meter is equipped with a 3.5 inches backlit LCD display.
*1 to 5 points calibration with automatic recognition for USA, NIST, and DIN buffers.
*Automatic electrode diagnosis shows the pH slope and offset.
ORP:
*1-point offset calibration allows adjusting the displayed value to a known standard.
*Relative and absolute millivolt modes ensure reliable ORP measurements.
Ion Concentration:
*2 to 5 points calibration, including the 8 concentration points can be selected.
*Direct ion concentration readout simplifies the measurement process.
*Automatic electrode diagnosis shows the calibration points and slopes.
*Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency. Conductivity/TDS/Salinity/Resistivity:
*1 to 5 points calibration with automatic recognition for conductivity standards.
*Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.
*Automatic electrode diagnosis shows the calibration points and factors.
Dissolved Oxygen:
*1 or 2 points calibration using the air-saturated water or zero oxygen solution.
*Salinity and barometric pressure compensations eliminate the measurement error. Other Features:
*Automatic temperature compensation ensures accurate readings over the entire range.
*Auto-Read function senses and locks the measurement endpoint.
*Calibration due alarm prompts user to calibrate the meter regularly.
*Auto-Power Off effectively conserves battery life.
*Setup menu allows setting the number of calibration points, resolution, stability criteria, temperature unit, date and time, etc..
*Reset function automatically resumes all settings back to the factory defaults.
*Expanded memory stores or recalls up to 500 data sets.
*USB communication interface is easy to transfer data to PC.
Multi-mode power scheme (batteries, power adapter and USB port) ensures that using the meter smoothly.
Accessories:
pH/conductivity/dissolved oxygen electrode, temperature probe, pH standard buffer, conductivity standard solutions, dissolved oxygen electrolyte, membrane cap, carrying case.
Technical Parameters:
| Model | PH-900P | |
| pH | Range | -2.000~20.000pH |
| Resolution | 0.001,0.01, 0.1pH, selectable | |
| Accuracy | ±0.002pH | |
| Calibration Points | 1 to 5 points | |
| pH Buffer Options | USA, NIST, DIN, 2 custom buffers | |
| ORP(optional) | Range | ±1999.9mV |
| Resolution | 0.1, 1mV, selectable | |
| Accuracy | ±0.2mV | |
| Calibration Points | 1 point | |
| lon(optional) | Range | 0.001 ~19999 (depending on the range of ISE) |
| Resolution | 0.001,0.01,0.1,1 | |
| Accuracy | ±0.5% F.S. (monovalent),±1%F.S. (divalent) | |
| Measurement Units | ppm, mg/L, mol/L, mmol/L | |
| Calibration Points | 2 to 5 points (0.001,0.01, 0.1,1,10, 100,1000, 10000) | |
| Conductivity | Range | 0.1 ~2卩S/cm(CON-0.1,optional); 2*-20mS/cm(CON-1 .standard); 20~200mS/cm(CON・10,optional) |
| Resolution | 0.001,0.01,0.1,1 | |
| Accuracy | ±0.5% F.S. | |
| Calibration Points | 1 to 5 points | |
| Calibration Solutions | 10pS/cm, 84pS/cm, 1413pS/cm, 12.88mS/cm, 111.8mS/cm | |
| Temperature Coefficient | Linear (0.0~10.0%/°C), pure water | |
| Reference Temperature | 20/25°C | |
| Cell Constant | K=0.1,1, 10 or custom | |
| TDS | Range | 0-10.00,100.0,1000ppm, 10.00, 200.0ppt |
| Resolution | 0.01,0.1,1 | |
| Accuracy | ±1%F.S. | |
| TDS Factor | 0.1-1.0 (default 0.5) | |
| Salinity | Range | 0.00~42.00psu, 0.00~80.00ppt |
| Resolution | 0.01 | |
| Accuracy | ±1%F.S. | |
| Resistivity | Range | 0.00~20.00MQ |
| Resolution | 0.01 | |
| Accuracy | ±1%F.S. | |
| DO | Range | 0.00~20.00mg/L, 0.0-200.0% saturation |
| Resolution | 0.01 mg/L, 0.1% | |
| Accuracy | ±0.2mg/L, ±2.0% | |
| Calibration Points | 1 or 2 points | |
| Barometric Pressure Correction | 60.0~112.5kPa/450~850mmHg, manual | |
| Salinity Correction | 0.0~50.0g/L, manual | |
| Other
Specifications |
Temperature Compensation | 0~100°C/32~212°F, manual or automatic |
| Memory | 500 data sets. USB communication interface | |
| Power Requirements | 3*1.5V AA batteries or DC5V power adapter | |
| Dimension | 170*85*30mm | |
| Net Weight | 300g | |
| Packing Size | 450*320*100mm | |
| Gross Weight | 2kg | |